Butterfly Valve Leakage, How To Close Tight?

Jun 10, 2026 Leave a message

The butterfly valve does not close tightly is one of the most troublesome problems on the spot. Internal leaks (dripping) and external leaks (slurping) can affect the process in small cases and force the entire production line to shut down in severe cases. A lot of people think about replacing valves when they encounter this problem, it's not really necessary. There are many reasons why valves do not close tight, and by addressing the root cause, more than 80% of the time, valve problems can be solved without replacing the valve.
First, find out: why aren't the valves closed tight?
Essentially, butterfly valve do not close tightly for one reason only-the disc and valve seat are not tightly sealed. However, there are at least six specific reasons for this seal failure, each requiring a completely different solution.
First: there are impurities on the surface of the seal. This is the most common reason and the easiest to solve. When the valve is closed, Rust, slag, and silt in the pipe between the butterfly plate and seat can be trapped, forcing the the sealing surface to open. This is particularly common with newly installed valves, which have been closed for a long time and are now being restarted.
Second: aging or damage of sealing ring. Soft sealing materials such as rubber and PTFE (PTFE) can age, harden, crack and lose their elasticity when immersed in media for a long time. This is especially true when ordinary nitrile rubber is used to resist high temperature vapour; butadiene quickly carbonizes and fails.
Class III: Electric actuator ultimate drift. The valve itself is fine, but the electric actuator had the wrong closing limit, causing the valve plate to close to 85 degrees before stopping, leaving a 15-degree gap as the leakage path. This is especially common with electric butterfly valves that have been in use for a year or two.
The connection between valve stem and butterfly plate is loose. The valve stem rotates, but the butterfly plate does not follow, creating a gap between the stem and the butterfly plate, and the sealing surfaces was naturally out of alignment. This is common in situations of frequent opening and closing and high vibration.
Fifth: Installation problems. The flange bolts were not tightened diagonally, resulting in body deformation; the pipe was not installed correctly and external forces pushed the disc away from thecenter; and the butterfly plate did not provide sufficient space to open and close at 90 degrees during installation, leaving the valve semi-open for a prolonged period of time, resulting in grooves on the surface of the valve being corroded by high-speed fluids.
Sixth: too much medium pressure. The high pressure difference between the valves causes the pressure to push the valve plate open when closed, "blowing" the sealing ring out of the seal. In this case, it is useless to simply repair the valve. A pressure regulator must be added to the back of the valve.
Emergency response: temporary leak stoppage, no parking.
If the production line cannot be shut down, the following three emergency measures should be taken first.
Measure 1: Adjust the limit switch. Manually fine-tune of the valve closing limit switch on the electric actuator panel increases the closing direction of travel by 1% to 3%. Be careful not to adjust too much or the valve plate will crush the sealing ring. This measure can only be used in the case of slight limit switch drift.
Second measure: Pulse purification. Compressed air with a pressure of 0.6 MPa or higher is introduced at the upstream flange of the valve and pulse cleaned at the edge of the valve plate and seat to remove impurities trapped between the sealing surfaces. This method is particularly suitable for dust collection systems and dust environments.
Third method: Repeat all opening and closing. Open the valve quickly and completely, then close it three to five times, using the scouring force of the medium itself to remove impurities. Simple and direct, but effective for minor jamming.
Root cause solutions: four types of problems, four fixes
Impurities clog: Remove valve and clean cavity to remove any foreign object between butterfly plate and valve seat. Check the sealing surface for scratches before reinstalling.
For aging seals: Replace valve seat seal directly. Replace the rubber valve seat of soft-sealed butterfly valves and the metal sealing surface of hard-sealed butterfly valves. When selecting a valve, make sure the valve is dielectric matched: EPD3 is water resistant, Fluororubber is corrosion resistant, and PTFE is heat resistant. Avoid using the wrong material.
Limit drift: Recalibrate the zero and full scale of the electric actuator and tighten the mechanical limit stop. If the positioning module is damaged, simply replace it; this can be done in two hours, much faster than replacing the entire valve.
Disassembly of stem and butterfly plate: Remove stem, tighten connection, check valve stem is bent. Straighten bent stem; replace stem if worn severely.
For installation: this is the most troublesome. The pipe coaxiality must be recalibrated and the flange bolts must be tightened evenly in diagonal order to ensure that the valve body is not deformed. If you do not provide enough open and closing space during installation, you need to return to work.
Prevention is ten times more valuable than repair. Eighty percent of butterfly valve malfunctions are preventable. Check the tightness and sealing of bolts every six months; for muddy water valves, open and close at a small angle each month to prevent sludge accumulation and blockage; calibrate the limiting switch for the electric actuator quarterly; keep the valve fully closed or open, not half open, when closed, which can lead to a a hot-state jamming and subsequent reboot.
In short: a malfunctioning valve doesn't necessarily mean it's broken, but it can get worse if ignored. Determine the cause before you act, and do not replace the valve immediately.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry